HUAWEI PAC600S12-EB 600W AC POWER MODULE(BACK TO FRONT POWER PANEL SIDE EXHAUST)
Item | Details |
---|---|
Description | 600 W AC&240 V DC Power Module |
Part Number | 02312FFU-002 |
Model | PAC600S12-EB |
Appearance
Version Mapping
Product | Product Model | First Supported Version |
---|---|---|
S5731-S | S5731-S24T4X (02353AHU) | V200R019C10 |
S5731-S | S5731-S24T4X (02353AHU-001) | V200R020C10 |
S5731-S | S5731-S24T4X (98011851) | V200R021C10SPC600 |
S5731-S | S5731-S32ST4X (98011813) | V200R021C01 |
S5731-S | S5731-S32ST4X (98011813-002) | V200R021C10SPC600 |
S5731-S | S5731-S48S4X (98011805) | V200R021C01 |
S5731-S | S5731-S48S4X (98011805-001) | V200R021C10SPC600 |
S5731-S | S5731-S48T4X (02353AJB) | V200R019C10 |
S5731-S | S5731-S48T4X (02353AJB-003) | V200R020C10 |
S5731-S | S5731-S48T4X (98011847) | V200R021C10SPC600 |
S5731S-S | S5731S-S24T4X-A (02353AHV) | V200R019C10 |
S5731S-S | S5731S-S24T4X-A (02353AHV-001) | V200R020C10 |
S5731S-S | S5731S-S24T4X-A (98011852) | V200R021C10SPC600 |
S5731S-S | S5731S-S32ST4X-A (98011814) | V200R021C01 |
S5731S-S | S5731S-S32ST4X-A (98011814-001) | V200R021C10SPC600 |
S5731S-S | S5731S-S48S4X-A (98011806) | V200R021C01 |
S5731S-S | S5731S-S48S4X-A (98011806-001) | V200R021C10SPC600 |
S5731S-S | S5731S-S48T4X-A (02353AJC) | V200R019C10 |
S5731S-S | S5731S-S48T4X-A (02353AJC-003) | V200R020C10 |
S5731S-S | S5731S-S48T4X-A (98011848) | V200R021C10SPC600 |
S5731-H | S5731-H24T4XC (02352QPP) | V200R019C10 |
S5731-H | S5731-H24T4XC (02352QPP-001) | V200R020C10 |
S5731-H | S5731-H24T4XC (02352QPP-005) | V200R021C10SPC600 |
S5731-H | S5731-H48T4XC (02352QPT) | V200R019C10 |
S5731-H | S5731-H48T4XC (02352QPT-003) | V200R020C10 |
S5731-H | S5731-H48T4XC (02352QPT-007) | V200R021C10SPC600 |
S5731S-H | S5731S-H24T4S-A (02353DJE) | V200R019C10 |
S5731S-H | S5731S-H24T4S-A (02353DJE-001) | V200R020C10 |
S5731S-H | S5731S-H24T4S-A (02353DJE-003) | V200R021C10SPC600 |
S5731S-H | S5731S-H24T4X-A (02353HVH) | V200R019C10 |
S5731S-H | S5731S-H24T4X-A (02353HVH-001) | V200R020C10 |
S5731S-H | S5731S-H24T4X-A (02353HVH-003) | V200R021C10SPC600 |
S5731S-H | S5731S-H24T4XC-A (02352YRG) | V200R019C10 |
S5731S-H | S5731S-H24T4XC-A (02352YRG-001) | V200R020C10 |
S5731S-H | S5731S-H24T4XC-A (02352YRG-003) | V200R021C10SPC600 |
S5731S-H | S5731S-H48T4S-A (02353DJG) | V200R019C10 |
S5731S-H | S5731S-H48T4S-A (02353DJG-003) | V200R020C10 |
S5731S-H | S5731S-H48T4S-A (02353DJG-005) | V200R021C10SPC600 |
S5731S-H | S5731S-H48T4X-A (02353HVJ) | V200R019C10 |
S5731S-H | S5731S-H48T4X-A (02353HVJ-003) | V200R020C10 |
S5731S-H | S5731S-H48T4X-A (02353HVJ-005) | V200R021C10SPC600 |
S5731S-H | S5731S-H48T4XC-A (02352YRF) | V200R019C10 |
S5731S-H | S5731S-H48T4XC-A (02352YRF-003) | V200R020C10 |
S5731S-H | S5731S-H48T4XC-A (02352YRF-005) | V200R021C10SPC600 |
S5732-H | S5732-H24S6Q (02353AJS) | V200R019C10 |
S5732-H | S5732-H24S6Q (02353AJS-001) | V200R020C10 |
S5732-H | S5732-H24S6Q (02353AJS-003) | V200R021C10SPC500 |
S5732-H | S5732-H24S6Q (02353AJS-004) | V200R021C10SPC600 |
S5732-H | S5732-H48S6Q (02353AJU) | V200R019C10 |
S5732-H | S5732-H48S6Q (02353AJU-001) | V200R020C10 |
S5732-H | S5732-H48S6Q (02353AJU-003) | V200R021C10SPC500 |
S5732-H | S5732-H48S6Q (02353AJU-004) | V200R021C10SPC600 |
S5735S-H | S5735S-H24S4XC-A (98011041) | V200R021C01 |
S5736-S | S5736-S24S4XC (98011038) | V200R021C01 |
S5736-S | S5736-S48S4XC (98011042) | V200R021C01 |
Panel
1. Lock |
2. Indicator |
3. Fan air vent |
4. Handle |
5. Airflow flag (air out) |
6. AC power socket |
- |
- |
Silkscreen | Name | Color | Status | Description |
---|---|---|---|---|
STAT | Running status indicator | - | Steady off | The power input is abnormal (for example, no input, overvoltage, or undervoltage) or the power output is abnormal (for example, overcurrent, overvoltage, short circuit, or overtemperature). |
Green | Steady on | The power module is working normally. |
Functions and Features
Function |
Description |
|
---|---|---|
Input protection |
Input undervoltage protection |
In this protection state, the power module stops supplying power. When the input voltage restores to the normal range, the power module automatically resumes power supply. |
Input overcurrent protection |
In this protection state, the power module stops supplying power and cannot automatically resume power supply when the input current restores to the normal range. |
|
Output protection |
Output overvoltage protection |
In this protection state, the power module stops supplying power intermittently. When the output voltage restores to the normal range, the power module automatically resumes power supply. |
Output overcurrent protection |
In this protection state, the power module supplies power intermittently. When the output current is within a range, the power module automatically resumes power supply. |
|
Output short-circuit protection |
In this protection state, the power module supplies power intermittently. When the short circuit is removed, the power module automatically resumes power supply. |
|
Overtemperature protection |
When the temperature of the power module exceeds a specified threshold, the power module stops supplying power. When the temperature falls into the normal range, the power module automatically resumes power supply. |
|
Hot swapping |
Supported |